SD 140 CPDDF 120
Technical data
Versions
SD 140 CPDDF 120 1:15 LB060015SD243L0
Single stage – Double Acting
TRANSMISSION RATIO 1:15
MAX DRIVE AIR PRESSURE : 10 Bar - 145 psig
DISPLACEMENT : 2 x 235 cc / 2 x 14,34 in³
MAX OUT PRESSURE : 414 Bar - 6000 psig
MIN SUCTION PRESSURE 5 Bar - 70 psig
SD 140 CPDDF 120 1:25 LB060025SD243K0
Single stage - Double Acting
TRANSMISSION RATIO 1:25
MAX DRIVE AIR PRESSURE : 10 Bar - 145 psig
DISPLACEMENT : 2 x 148 cc / 2 x 9,03 in³
MAX OUT PRESSURE : 414 Bar - 6000 psig
MIN SUCTION PRESSURE 5 Bar - 70 psig
SD 140 CPDDF 120 1:43 LB060043SD243J0
Single stage - Double Acting
TRANSMISSION RATIO 1:43
MAX DRIVE AIR PRESSURE : 10 Bar - 145 psig
DISPLACEMENT : 2 x 42cc / 2 x 2,56 in³
MAX OUT PRESSURE : 414 Bar - 6000 psig
MIN SUCTION PRESSURE 5 Bar - 70 psig
SD 140 CPDDF 120 1:62 LB100062SD243I0
Single stage - Double Acting
TRANSMISSION RATIO 1:62
MAX DRIVE AIR PRESSURE : 10 Bar - 145 psig
DISPLACEMENT : 2 x 30cc / 2 x 1,83 in³
MAX OUT PRESSURE : 689 Bar - 10000 psig
MIN SUCTION PRESSURE 5 Bar - 70 psig
SD 140 CPDDF 120 1:97 LB150097SD243H0
Single stage - Double Acting
TRANSMISSION RATIO 1:97
MAX DRIVE AIR PRESSURE : 10 Bar - 145 psig
DISPLACEMENT : 2 x 18cc / 2 x 1,09 in³
MAX OUT PRESSURE : 1034 Bar - 15000 psig
MIN SUCTION PRESSURE 5 Bar - 70 psig